• 11-50 N Blue Screen Tension Meter Screen Tensiometer
  • 11-50 N Blue Screen Tension Meter Screen Tensiometer
  • 11-50 N Blue Screen Tension Meter Screen Tensiometer
  • 11-50 N Blue Screen Tension Meter Screen Tensiometer
  • 11-50 N Blue Screen Tension Meter Screen Tensiometer
  • 11-50 N Blue Screen Tension Meter Screen Tensiometer

11-50 N Blue Screen Tension Meter Screen Tensiometer

Certification: ISO, CE
Usage: For Man Roland Printer, For Komori Printer, For Heidelberg Printer, Screen Printing
Transport Package: Export Carton
Specification: 0-50N/cm
Trademark: MACROKUN
Origin: China
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
MK-RTM
Production Capacity
10000/Year

Product Description

11-50 N Blue Screen Tension Meter Screen Tensiometer
Screen Tensiometer
Model: TITAN
The ITAN screen tension meter has been calibrated to zero before leaving the factory.
Users do not need to adjust it by themselves.

The tension of the net is expressed in N / cm, which indicates how much the tensile
force of the mesh yarn per cm width is usually expressed in N-Newton or Kg-kg.

Newton shows the actual meaning of the tensiometer; the reading display method:
The first reading of the tensiometer reading is incorrect. The second reading of the
tensiometer is normal and the tensiometer should be flicked. Mesh next to it.
PRODUCT INFORMATION
Product Name: Mechanical tensiometer
Measurement error: ± 0.5N/CM
Measuring Range: 11-50N/cm
Units Of Measurement: N/cm
Accessories: Standard calibration glass
Net Weight: About 650 g
Total Weight: About 1150g
Package Size: 182*145*76mm
Note Shockproof: Put it on its side after use
Type of mesh Ty pes of printing Tension IN / CM
Ultra high tension mesh Circuit board and measuring scale 16-20
High-strength mesh Multi-color four-color
overprinting machine printing
16-20
High precision ultrafine mesh High-precision
multilayer circuit printing
25-30
High-precision polyester
mesh standard monofilament
Multi-color and
four-color overprint
8-12
Ordinary polyester
mesh standard monofilament
Flat objects 8-12
PRODUCT DETAILS
11-50 N Blue Screen Tension Meter Screen Tensiometer
Features of TITAN wire mesh tensiometer:

TITAN tension meter is suitable for the measurement of various screen tension,
Pointer indicating tension, unit: N/CM. The tension at any place of the tensioned
cloth can be detected, the radial tension and weft tension of the measured screen
can be distinguished, make the screen to reach the same tension in the latitude and
longitude direction. TITAN tension meter is a precision instrument, it needs to be kept dry and idust-free, and need to pay attention to anti-fall and anti-shock.
Tensiometer Accessories
1. Zero adjustment disc
2.0 N / cm (zero point)
3. Glass calibration block
4. Induction device
11-50 N Blue Screen Tension Meter Screen Tensiometer
11-50 N Blue Screen Tension Meter Screen Tensiometer
Measurement Methods And Steps
Zero adjustment

Before using the tensiometer to calibrate the tension meter, place the tensiometer
on the front of the zero adjustment plate(Do not use too much effort),Turn the scale
lock counterclockwise by hand until the scale disc rotates.Rotate the dial until the dot
is pointing to the pointer, and then turn the scale lock clockwise to lock the scale.
(Note: 1. Scale in the zero when the long needle is not necessarily and the horizontal
line into 90 degrees, left partial right is normal.2. Daily use, such as zero adjustment
plate appears large gap or broken should be replaced.

Measuring

The steel mesh or screen plate non-printed surface up on the platform.
The entire tension meter on the smooth side of the outer frame 15-20cm on the net
surface.With a finger to tap the stencil or wire mesh surface a few times, then the
pointer is the point of view of the current stencil or wire mesh on the actual tension
(Newton readings).Place the steel screen or screen version horizontally (PCB contact
or screen print side up),Place the tension meter in the steel mesh or screen version of
the four corners and center, check the point of the tension value, and the minimum
value fill (stencil or screen use resume).Check whether the measured value of steel
mesh or screen tension is within the allowable range , if the measured value is not
standard, the feedback engineer handles.
11-50 N Blue Screen Tension Meter Screen Tensiometer
Note

When testing the tension, the wire mesh must be suspended;
The tensiometer needs to be zeroed before use.
It is forbidden to add lubricant to any part.
Pay attention to shock. If the instrument is dropped, it may damage or reduce the
measurement accuracy and sensitivity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now